The following is a list of permit types available in Sumter County. Clicking on the permit type will show the submission requirements of that permit. Please note that prior to issuance of any building permit, a permit or letter of clearance is required from Environmental Health.

Permit Types

Residential - Conventional Construction
Residential - Mobile Home
Residential - Additions
Re-roof/Roof-over
Accessory Building/Structure (Includes Pools)
Plumbing
Electrical
Mechanical (A/C)
Gas
Sign
Commercial
Commercial - Additions

Non-residential Farm Building Exemption from Building Code Requirements:

 

Submission Requirments

Submission Requirements for Conventional Construction

Site Plan
Two sets of building plans (Engineer sealed or 10-97 Wind load calculations)
State energy code w/ Manual J (if central heat/air system)
Septic tank permit
Copy of recorded deed
Driveway permit, if applicable
Flood Zone Acknowledgement, if applicable

Back to Top

Submission requirements for Mobile Home

Site Plan
Blocking Diagram
Septic tank permit
Copy of recorded deed
Driveway permit, if applicable
Pre-inspection form, if applicable
Document showing size & age of mobile home (copy of title or purchase
agreement) Maximum of three years of age if being located in the City of
Bushnell.
Skirting Diagram (Class A only)
Notarized Letter/Affidavit (*If required)
Flood Zone Acknowledgement, if applicable

*There are three different situations in which a notarized letter/affidavit is required:
1. A notarized letter from the property owner is required if the mobile home is in a different name.
2. A notarized letter from the Mobile Home Installer is required if the property owner is pulling the permit under the installer's name.
3. A notarized letter is required if the Mobile Home Installer is doing the set-up, but the property owner is doing the electric, plumbing, or mechanical work.

Back to Top

Submission requirements for Additions

Site plan
Two sets of building plans (Engineer sealed or 10-97 windload calc.)
Septic tank permit
State energy code w/ Manual J (if central heat/air system)
Copy of recorded deed
Flood Zone Acknowledgement, if applicable

Back to Top

Submission requirements for Re-roof/roof-over

Square footage of the re-roof and type of materials
Building plans, if a roof-over
Copy of recorded deed

Back to Top

Submission requirements for Accessory Building/Structure (Includes Pools)

Site Plan
Two sets of building plans (Engineer sealed or windload calc.)
Septic tank permit, if applicable
State energy code w/ Manual J (if central heat/air system), if applicable
Copy of recorded deed
Flood Zone Acknowledgement, if applicable

Swimming pool permit applications require that the applicant complete and sign the "Residential Swimming Pool Safety Act" form.

Back to Top

Submission requirements for Plumbing

Existing building permit number, if applicable
Copy of recorded deed if no existing building permit number
Plumbing plan

Back to Top

Submission requirements for Electrical

Existing building permit number, if applicable
Copy of recorded deed if no existing building permit number
Electrical plan
For pump service, list amp size, panel size, breaker size, and wire size

If the permit application is for agricultural purposes, a signed and notarized affidavit is required.

Back to Top

Submission requirements for Mechanical

Existing building permit number, if applicable
Copy of recorded deed if no existing building permit number
Indicate the use

Back to Top

Submission requirements for Gas

Existing building permit number, if applicable
Copy of recorded deed if no existing building permit number
List the tank size

Back to Top

Submission requirements for Commercial Structures and for Commercial Additions

One site plan
Three sets of plans, four if located in the City of Bushnell. If the facility (restaurant, etc.) requires state approval then, four sets of plans, five if located in the City of Bushnell. (Engineer sealed)
State energy code w/ Manual J (central heat/air system), if applicable
Fire Safety Data Sheet
Septic tank/DEP permit
Copy of recorded deed
Copy of SWFWMD permit
Driveway permit, if applicable
Flood Zone Acknowledgement, if applicable

Back to Top

Submission requirements for Signs

Site plan
Two sets of building plans
Copy of recorded deed

Back to Top

 

Division of Planning & Development
Board of County Commissioners, Sumter County, Florida

PH: 352-793-0270 | FAX: 352-793-0274
910 North Main Street, Suite 301, Bushnell, FL 33513

This Site is maintained by the Information Technology Department
For questions or problems with this site, please contact the Webmaster

Last Updated: May 13, 2008 3:11 PM

Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact this office by phone or in writing.

BOCC Logo

 

home | planning & development | contact us | why sumter? | planning | zoning
building | contractor licensing | code compliance | housing